HT Standalone Series Online UPS 10-40kVA

Call for price

HT series three phase UPS applies advanced technology that increases performance and reliability.

Description

HT series three phase UPS applies advanced technology that increases performance and reliability: two high speed DSPs with completed digital control fully ensure high quality of power supply, high input power factor and low input current distortion, the HT series is providing more safety to critical load.

APPLICATIONS

IDC(Internet Data center),ISP,IT Room, Service Center, Precision instruments,Intelligent equipments

Main Feature

  • High input PF>0.99;Input current THDi<4%
  • Muti-protection, over-temperature protection with 8 sensors, over-load, battery under voltage, fan failures, short-circuit
  • Four circuit breakers, providing full protection when fault happens
  • Battery management: smart charging control, auto maintenance, greatly extend the battery life
  • Parallel up to 8 units
  • Friendly operation interface, high-resolution LCD screen

SPECIFICATIONS

MODEL HT33010XL HT33015XL HT33020XL HT33030XL HT33040XL
HT33010XS HT33015XS HT33020XS HT33030XS HT33040XS
System Capacity 10kVA 15kVA 20kVA 30kVA 40kVA
Input Dual Input Standard
Phase 3 Phase+Neutral+Ground,
380V/400V/415V(line-line)
Input Voltage Range 304~478Vac (line-line),full load;

228V~304Vac (line-line),load decreases linearly according to the min
phase voltage

Rate Frequency 50/60Hz
Input Frequency Range 40Hz~70Hz
Input PF >0.99
Input THDi <4% <3%
Bypass Rate Voltage 380/400/415VAC  (line-line)
Rate Frequency 50/60Hz
Input Voltage Range Settable, -40%~+25%
Bypass Frequency Range Settable, ±1Hz, ±3Hz, ±5Hz
Bypass Overload 125% long term operation; 130% for 10 mins;
150% for 1 min
Output Rate Voltage 380/400/415VAC  (line-line)
Voltage Regulation 1% for balance load; 1.5% for unbalance load
Rate Frequency 50/60Hz
Frequency Precision 0.1%
Output PF 1 0.9
Output THDu <1% , Linear load; <5.5%, Non-linear load
Crest Factor 3:1
Inverter Overload 110% for 1 hour; 125% for 10 mins ;150% for
1 min; >150% for 200 ms
Battery Voltage ±240VDC
Battery Number 40pcs (Settable: 32pcs-44pcs)
Voltage Precision ±1%
Charge Power up to 20% * Output active power
Battery Cold Start Optional
System Efficiency AC Mode 95.0% 96.0%
ECO Mode 98.0%
Battery Mode 95.0% 96.0%
Display LCD + LED + keyboard
IP Class IP 20
Interface RS232,RS485
Option SNMP Card, Parallel kit, USB, Programmable
Dry Contact
Temperature Operation: 0~ 40 ℃  Storge: -40 ~70 ℃
Relative Humidity 0 ~95% Non-condensing
Altitude <1000m. Within 1000m to 2000m, power derate
1% for every 100m rise
Noise (1 meter) 55dB @ 50% load
Applicable Standards Safety: IEC/EN 62040-1-1 EMC: IEC/EN
62040-2  Performance: IEC/EN 62040-3
Physical Weight (kg) 51.5 51.5 89 89 140
31 31 50 52 61
Dimension W*D*H (mm) 250*840*715 250*840*715 350*738*1335 350*738*1335 500*840*1400
250*660*530 250*660*530 250*680*770 250*680*770 250*836*770