NU33RM Modular Series Online UPS 10-90kVA

Call for price

Description

The rack modular, scalable, hot-swappable, online double conversion UPS ranging from 10 to 90kVA, with its flexible configuration of 3/3, 3/1 and 1/1, compact structure, is the ideal choice for small and medium data center.

APPLICATIONS

Small and medium data center and offices

Main Feature

Rack modular design

Modular design, compatible with 19” standard rack cabinet, convenient to be
integrated with servers

High power density

10/15kVA power module in 2U height, saving great amount of space, easy for
capacity expansion

Integrated solution for data center

UPS can be integrated with battery cabinet, PDU and external maintenance
bypass, offering excellent choice for data center

Intelligent charging management

The system intelligently control the whole process of the charging and
discharging, effectively improving the life time of the battery

Flexible configuration

The system based on 10kVA power module can be configured to 3/3, 3/1 and 1/1
without derating

Friendly interface

7” touch color LCD with graphic display, more information displayed and
easier for customer to operate

Smart sleep function

System can intelligently shutdown some power modules to increase total load
rate, achieving higher efficiency

Self-aging mode

Energy internal circle technology, system can run with full load ,saving more
than 90% energy

SPECIFICATIONS

MODEL

NU020/10X

NU030/15X NU040/10X NU045/15X NU060/10X  NU090/15X
System Capacity 20kVA 30kVA 40kVA 45kVA 60kVA 90kVVAA
Power Module Capacity 10kVA/10kW 15kVA/15kW
Input Dual Input Standard
Phase 3 Phase+Neutral+Ground, 380V/400V/415V(line-line)
Input Voltage Range 304~478Vac (line-line),full load;228V~304Vac (line-line),load decreases linearly according to the min phase voltage
Rate Frequency 50/60Hz
Input Frequency Range 40Hz~70Hz
Input PF >0.99
Input THDi <4% (100% Linear load)
Rate Voltage 380/400/415VAC  (line-line)
Rate Frequency 50/60Hz
Input Voltage Range Settable, -40%~+25%
Bypass Bypass Frequency Range Settable, ±1Hz, ±3Hz, ±5Hz
Bypass Overload 125% long term operation; 130% for 10mins ; 150% for 1 min; >150% for 300ms 110% long term operation; 130% for 5mins ; 150% for 1 min; >150% for 300ms
Output Rate Voltage 380/400/415VAC  (line-line)
Voltage Regulation 1% for balance load; 1.5% for unbalance load
Rate Frequency 50/60Hz
Frequency Precision 0.1%
Output PF 1
Output THDu <1% , Linear load; <5.5%, Non-linear load
Crest Factor 3:1
Inverter Overload 110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms
Battery Voltage ±240VDC
Battery Number 40pcs (Settable: even number from 32 to 44)
Voltage Precision ±1%
Charge Power up to 20% * Output active power
Battery Cold Start Optional
System Efficiency AC Mode 95.0%
ECO Mode 98.0%
Battery Mode 94.5%
Display 7.0″ color touch screen LCD + LED + keyboard
IP Class IP 20
Interface RS232,RS485, Programmable Dry Contact
Option SNMP Card, Parallel kit, SPD, Power module with battery cold start function
Temperature Operation: 0~ 40 ℃  Storge: -40 ~70 ℃
Relative Humidity 0 ~95% Non-condensing
Altitude <1000m. Within 1000m to 2000m, power derate 1% for every 100m rise
Noise (1 meter) 56dB @ 50% load
Applicable Standards Safety: IEC/EN 62040-1-1 EMC: IEC/EN 62040-2  Performance: IEC/EN 62040-3
Physical
Weight (Kg) Cabinet 42 42 51 55 85 85
Power Module 15.3 15.5
Dimension W*D*H (mm) Cabinet 458*697*398 458*697*398 458*697*575 458*751*575 485*751*1033 485*751*1033
Power Module 436*590*85